| Syringe Infusion Pump (TIASHI - SP) |
Your are here sstechnomed.com Home Infant Care Infusion Pump Various Models Syringe Infusion Pump |
|
| Self-explanatory control panel |
| The control panel is self-explanatory with abbreviated operating instructions on LCD, Easy-to-rcad liquid-crystal displays all essential data in large size numbers, reducing the chance of erroneous readings, LCD provided with backlight for viewing in dark environments. |
| Selectable three-step occlusion detection pressures |
| As versatile as they are reliable, these syringe pumps provide selectable, pressure level settings to match virtually any requirement Low, Mid high-occlusion setting. |
| "Keep-Vien-Open" function |
| When the preset volume is reached, the pump automatically engages the 'Keep Vein Open' automatically (KVO) function, Infusion rate in KVO is 1% but not less than 0. 1 ml/hr. This prevent the infusion line from blocking due to blood clots. |
|
 |
| Preset Bolus Rate |
| A simple and safe Bolus function enabling the delivery of the shock does at any moment of the infusion with the preset rate as under, 300ml/hrfor lOmi syringe, 500ml/hrfor20ml syringe, 700m1/hr for 30ml syringe, lOOOml/hrfor 50/60ml syringe. Full information about the course of infusion
Visual display of all the programmed parameters and infusion data such as syringe type and volume, the infusion rate, the infused volume, time remaining till the end of infusion and occlusion pressure limit. |
| Ultimately 5 minutes prior the end of infusion |
| Alarm announcing the necessity to prepare another dose of the drug. |
| Volume memory function |
| In Memory Mode, this convenient feature retains the previously selected data of delivery rate and limit so they do have to be re-entered. This not only saves time and effort but also helps reduce errors. |
| External Switching mode power supply |
| Complying with high standards, that assures a low and high voltage working environment, another important feature of the unit. A built in battery Guarantees safe operating of the pump in case of mains failure. When patient is being ransported. |
| Easy set-up on infusion stand |
| The model TIASHI-SP can easily be poly-mounted, or set a table for more convenient access. |
| Technical Specifications |
| Infusion |
| Overall Accuracy* |
+/-2%(Measured time>l hr, min 0.2 ml) |
| Pumping mechanism |
Lead screw mechanism |
| Flow rate ranges |
0.1-200 ml/hr for 50/60 ml syringe
0.1 -120 rnl^r for 30 ml syringe
0.1 -100 ml/hr for 20 ml syringe
0.1 -060 mlyrtir for 10 ml syringe |
| Infusion volume limit |
60 ml, Programmable every 0.1 ml |
| Bolus rate |
Up to 1000 ml/hr |
| Occlusion pressure limit |
Programmable three level
LowO.4 +/- 0.08 kg/cm2 (bar)
medium 0.9 +/-020 kg/cm2 (bar)
High 1.2 +/• 025 kg/cm2 (bar) |
| KVOrate |
1 % of selected infusion rate but min.0.1 ml/hr |
| Syringe type |
| BD |
10/20/50/60 ml |
| Dispovan |
10/20/50 ml |
| Terumo |
10/30/50/60 ml` |
| Pharma |
10/50 ml |
| Perfuser |
50ml |
|
| Indicators |
| Alarms |
Run & Mains
No mains, Very low battery, Occlusion
No syringe, Idle, Near End,End of infusion, KVO |
| Power |
| External power supply |
AC Input range 170 - 270 VAC, Frequency 50 - 60 Hz Output: 12VDC -1 Amp |
| Power Consumption |
12 Watts max. |
| Build in battery |
Ni - MH battery for increased durability. |
| Battery life |
Continuous operation for about 20 hrs. at an operating rate of 5 ml/hr, under standard conditions |
| Classification |
Class II, IPX (Drip Proof) |
| Operating Conditions |
Ambient Temperature: 05 to 40° C
Relative Humidity20 to 90 % (no condensation)
Atmospheric pressure: 70 to 106 kPa |
| Housing & construction |
| Compact and Robust F.R.P |
| Weight |
Appro. 2.2 Kgs. |
| Dimensions |
Appox. 265L, llOH, 150W (mm) |
| Mounting |
On a pole or bed-frame |
|
* As per IEC standard (i0601-2-24
** Optional feature
Specifications and appearance are subject to changes without prior notice. |
|
|