| Drop Infusion Pump (TIASHI - DP) |
Your are here sstechnomed.com Home Infant Care Infusion Pump Various Models Drop infusion pump(TIASHI - DP) |
|
| Application: |
| Continuous low flow rate infusion of fluid drug and transfusion in ICU or CCU, Continuous infusion of anesthetic, anti-cancer agent and nutrient to immature infant or newborn.s |
| The handy drop pump |
| Small Size, low weight and high-technology, incorporated into a compact design. Quick and simple mounting at the bedside, via universal clamp. |
| Three different modes for Infusion |
| • Simple Drop Rate Mode • Volume Target Mode • Time Target Mode.
Customizable setup as per user's choice: 4-factory preset and 4 customized IV sets library along with facility to set default infusion set.. 5 levels for Alarm sound tone • 5 levels for K.V.O. flow rate • 5 levels for Keypad tone • ml/hr or Drops/min unit selection for Volume Target and Time Target mode' Facility to set default infusion mode for simplicity |
|
 |
| Self-testing Function |
| After power is turned on, the microprocessor in the TIASHI-DP automatically executes a self-diagnostic in order to ensure that all functions are working properly That also monitors every corner during infusion |
| Easy identification of alarm condition |
Obvious and recognizable attention lights Flashing Back-light of LCD display for Audible and Visible alarm function. |
| Free Flow Protection |
Tubing clamp (Stopper) mechanism automatically closes the IV tubing to prevent unrestricted flow of solution to the patient when the door is opened. |
| Keep-Vein-Open Function |
When Infusion is completed, the pump automatically engages the K.V.O. function to maintain a minimum flow rate of 1 ml/h or 1 Drops/min. This prevent the Infusion line from blocking due to blood clots. |
Communication Port: RS - 232C connector for external communication and to upgrade. |
| Easy Battery Replacement |
| The battery pack can easily be replaced simply by opening the battery cover at the back of the unit. |
| External DC power Compatible: |
| Connects to external DC power source, enabling use of the pump within an ambulance. |
| Air bubble detector (Optional |
Air bubble detector can detect bubble size between SO to 1S0 micro liter (User settable). Alarm available for air bubble volume accumulated overtime (1 ml over 0.5h). |
| Improved Drop Sensor |
The drop sensor controls flow rate of IV fluid, and detect irregularities in drop count. Digital signal processing for better perfomance. |
| Technical Specifications |
| Infusion |
| Overall Accuracy* |
+/- 1 % |
| Setting Modes |
Flow rate only, flow rate + volume target, time + volume target |
| Flow rate ranges |
0 -300 drops/min or 0 -300 ml/hr. |
| Infusion volume limits |
0 -60000 drops or 0 -10000 ml |
| Time range |
0 -99:00 hrs |
| KVO rate |
1 to 5 % of selected infusion rate but min. 1 drop/ min or 1 ml/hr |
| Mechanical |
| Pumping Mechanism |
Linear Peristaltic |
| Drop Sensor |
External |
| Air Bubble Detector** |
Ultrasonic Adjustable 20- 150µ1 15, 20, 40, 60 drops/cc. |
| Set type |
Facility to add four customized sets as per user's choice. |
| Indicators |
|
| Alarms |
Run & Mains. No mains, Very low battery, Low battery, Sensor error, Low flow, High flow, Door open, Near End, End of infusion, KVO, Air in line**, System error. |
| Special Features |
| Free Flow Protection |
A unique lever mechanism protects from free flow in case of accidental door opening. |
| Digital Processing of Drop Sensor Signal |
Digital processing of drop sensor signals allows you to the change the infusion parameters without the need for infusion interruption. |
| Adjustable air in line alarm threshold * |
The size of air bubble to be detected can be set in the range of 20 to 150µ1 |
| Flow Rate & Volume Unit selection |
Option to select Flow Rate Unit in terms of drop/mill or ml/hr & Volume Unit in terms of drops or m1. |
Power |
| External power supply |
AC Input range170 -270 VAC, Frequency 50 -60 Hz
12 Volts, l Amp DC output Supply |
| Power Consumption |
12 Watts max. |
| Build in battery |
8.4 V, 2.1 AHr Ni -MH battery for increased durability.
Continuous operation for about 4.5 hrs. at an operating rate of 20 drops/mill or 20 ml/hr with assign I. V. Set under standard conditions. |
| Classification |
Class II, IPX1 (Drip Proof) |
| Operating Conditions |
Ambient Temperature 05 to 40° C Relative Humidity 20 to 90 % (no condensation) Atmospheric 70 to 106 kPa pressure |
| Housing & construction |
| Compact and Robust A.B.S Plastic |
| Weight |
Approx. 2.4 Kgs. |
| Dimensions |
Approx. 250 (L), 245 (H), 90 (W) |
| Mounting |
On a pole or bed-fra |
|
* As per IEC standard (i0601-2-24
** Optional feature
Specifications and appearance are subject to changes without prior notice. |
|
|